Optris Logo - Affordable temperature measurement solutions
tune

Product Configurator

Finding the perfect Optris product for your needs.

IR Thermometer Configurator arrow_forward IR Camera Configurator arrow_forward
Configurator Screen
lens_blur

Optics Calculator

Use the Calculator to quickly determine the right spot size for your needs.

Explore Now arrow_forward
Calculator Screen
forum

Chat with Engineers

Online service support

Chat Now arrow_forward
call

Call Us

Sales department:
+1 603 766-6060

mail

Email Us

Sales department:
sales@optris-ir.com

Contact Us arrow_forward
construction

Request a Repair

Service request for repair orders:
support@optris-ir.com

Service Request Form arrow_forward

Industrial Process Interface for USB-native Optris Infrared Cameras

The industrial process interface (PIF) enhances functionality with 500 VAC isolation voltage for safety.

The industrial process interface (PIF) enhances functionality and flexibility in industrial environments, providing 500 VAC isolation voltage between the infrared camera and the process for safety and reliability. It supports three analog or alarm outputs, two analog inputs, and one digital input, enabling various control and monitoring applications. The interface includes fail-safe mechanisms to monitor conditions such as cable interruptions and software shutdowns, triggering alarms when necessary. Analog inputs can be used for parameters like emissivity setting and ambient temperature compensation, while analog and digital outputs can handle statuses such as frame sync and alarm conditions. Additionally, it features a robust design with an IP65 rating, making it suitable for harsh environments.
  • Enhances analog and digital integration options
  • Supports three analog/alarm outputs
  • Supports two analog inputs, one digital input
  • 500 VAC isolation for safety
  • Integrated fail-safe mechanisms

From $275.00

excl. sales taxes, custom tariffs and shipping

Product Description

The industrial process interface (PIF) enhances functionality with 500 VAC isolation voltage for safety. It supports three analog/alarm outputs, two analog inputs, and one digital input for diverse control and monitoring. Fail-safe mechanisms trigger alarms for issues like cable interruptions. Analog inputs handle parameters like emissivity, while outputs manage statuses such as frame sync and alarms. IP65-rated, it’s ideal for harsh environments.

  • Enhances analog and digital integration options
  • Supports three analog/alarm outputs
  • Supports two analog inputs, one digital input
  • 500 VAC isolation for safety
  • Integrated fail-safe mechanisms
Specification

General Specification

Environmental rating: IP65 (NEMA-4)
Operating temperature: -30 C … 85 C
Storage temperature: -30 C … 85 C
Relative humidity: 10 – 95 %, non-condensing
Protection class: IP65
Vibration: IEC 60068-2-6 (sinusoidal form), IEC 60068-2-64 (broadband noise)
Shock: IEC 60068-2-27 (25 G and 50 G)
Weight: 610 g (with 5 m cable)
Size: 122 x 70 x 27 mm
Cable length: 5 m high-temperature cable (standard), optional 10 m and 20 m

Electrical Parameters

Power supply: 5 … 24 VDC
LED display: 2 green LEDs for power and fail-safe 3 red LEDs for alarm relay status
Isolation: 500 V AC RMS between the infrared camera and process
Outputs: 3x analog / alarm outputs, 3x alarm relays
Inputs: 2x analog inputs,1x digital input
Ranges:
0/4-20 mA (for AO 1 – 3)
0 – 30 V / 400 mA (for alarm relays DO 1 – 3)
0 – 10 V (for AI 1 – 2)
24 V (for DI)

Programmable features

Analog inputs:
• Emissivity setting
• Ambient temperature compensation
• Reference temperature
• Uncommitted value
• Flag control
• Triggered snapshots, triggered recording, triggered line scan camera triggered event grabber
• Reset peak-/valley-hold

Digital input:
• Flag control
• Triggered snapshots, triggered recording, triggered line scan camera, triggered event grabber
• Reset peak-/valley-hold

Analog outputs:
• Main measure area
• Measure area
• Internal temperature
• Flag status
• Alarm
• Frame sync.
• Fail-safe
• External communication
• Center pixel (direct output)

Downloads
FAQs

What is the difference between the standard PIF and the industrial process interface?

The industrial process interface offers enhanced features such as 500 VAC isolation, multiple analog and digital inputs/outputs, and fail-safe mechanisms for monitoring various conditions, while the standard process interface has basic functionality with fewer input/output options.

What input and output capabilities does the industrial process interface lack compared to the standard process interface?

The industrial process interface supports up to three analog/alarm outputs, two analog inputs, and one digital input, along with fail-safe relay outputs. The standard interface typically has fewer input/output options and lacks some of these advanced features.

How many outputs and inputs does the interface support?

It supports up to three analog/alarm outputs, two analog, and one digital input.

What fail-safe mechanisms are integrated into the interface?

The interface monitors conditions like cable interruptions and software shutdowns, triggering alarms when necessary.

Is this process interface stackable?

No, this interface cannot be cascaded for USB infrared cameras.

Is this interface compatible with all Xi series cameras?

No, it is only designed for USB-based infrared cameras, which include the PI series and the Xi 400 or Xi 640.

Scope of Supply
  • 1x Industrial Process interface with connection cable
Related Products

COMPARE:

Compare